Crompton-controls M10 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Moniteurs Crompton-controls M10. Crompton Controls M10 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Shaft Power Monitor

Emotron M10Shaft Power MonitorInstruction manualEnglish

Page 2

8 Wiring Emotron AB 01-2550-01r35 WiringThe following wiring diagram provides an example of how the Emotron M10 can be connected to control the start/

Page 3 - Contents

Emotron AB 01-2550-01r3 Wiring 9HintIf the START/STOP is connected as per Fig. 1, it is recommended that termi-nals 6 and 7 be bypassed during setting

Page 4 - 2 Emotron AB 01-2150-01r3

10 Wiring Emotron AB 01-2550-01r35.1 Latched or un-latched alarmFig. 3 Wiring example for latched or un-latched alarm.When using DC voltage, alternati

Page 5 - 1 Inside the box

Emotron AB 01-2550-01r3 Selecting the current transformer 116 Selecting the current transformer6.1 For motors up to 50 A1. Check the rated motor curre

Page 6

12 Selecting the current transformer Emotron AB 01-2550-01r3Fig. 4 Example CTM 025 with 2 windings for a 12 A motorFig. 5 Example 1, 2 and 3 windings.

Page 7 - 3 Description

Emotron AB 01-2550-01r3 Operation 137 OperationMake sure that the enclosed plastic (rubber) insert (if ordered, optional) covers the monitor terminals

Page 8 - 4 Getting Started

14 Operation Emotron AB 01-2550-01r37.2 Auto SetThe alarm load level is automatically set by the Auto set function, see Chapter 8 The value for a para

Page 9

Emotron AB 01-2550-01r3 Operation 15The Emotron M10 is a single function monitor intended for machine builders and OEMs. It is the ideal choice for pr

Page 10 - 5 Wiring

16 Programming Emotron AB 01-2550-01r38ProgrammingSet-up and program the Emotron M10 according the "Example" on page 17, see also table 2, p

Page 11

Emotron AB 01-2550-01r3 Programming 17When the Emotron M10 is installed, the machine is running, and the normal machine load level is exceeded, the in

Page 13 - 6.1 For motors up to 50 A

18 Programming Emotron AB 01-2550-01r3More hints• If the alarm level is difficult to set - simply perform an Auto Set when the motor is stopped. Then

Page 14

Emotron AB 01-2550-01r3 Programming 19Fig. 7 Alarm level and margin.Table 3 Setting of rated motor power.Setting Rated motor power in kW or HP00 - 0.5

Page 15 - 7 Operation

20 Parameter list Emotron AB 01-2550-01r39 Parameter listTable 4 Parameter listParameterFactory settingActual setting Alt. settingRated power 64Relay

Page 16

Emotron AB 01-2550-01r3 Parameter list 219.1 Terminals1) Note! Terminals 1 and 2 (S1, S2) carry line voltage.2) N must be connected to terminal 11 and

Page 17

22 Technical data Emotron AB 01-2550-01r310 Technical dataDimensions (WxHxD)45x90x115 mm (1.77" x 3.54" x 4.53")Mounting 35 mm DIN-rail

Page 18 - 8Programming

Emotron AB 01-2550-01r3 Technical data 23*)Please note that these are separate voltage units; see table 6 with ordernumbers 10.0.1 Technical Data for

Page 19

24 Technical data Emotron AB 01-2550-01r3Fig. 8 Current Transformer CTxxx.10.0.2 Accessories and documentationOrder number Designation01-2471-10 Curre

Page 20 - More hints

Emotron AB 01-2550-01r3 Technical data 2510.1 Dismantling and disposalThe product is designed to comply with the RoHS directive, and shall be hand-led

Page 21 - Overload protection

26 Service Emotron AB 01-2550-01r311 ServiceThis manual is valid for the following model:Emotron M10.Emotron AB reserves the right to alter product sp

Page 22 - 9 Parameter list

Emotron AB 01-2550-01r3 Appendix 2712 AppendixFig. 9 M10 connection example 58762113119CTMxxxL3L2L1K1K1RESS1 S2L2L3L1 CNONCM10UVWMK1Max. 240 VAC (alt.

Page 23 - 9.1 Terminals

Emotron AB 01-2150-01r3 1Contents1 Inside the box ... 32 Safety ...

Page 24 - 10 Technical data

28 Appendix Emotron AB 01-2550-01r3Fig. 10 M10 single-phase connection exampleK1LNMM10NCNOCL1L3L2S2S1RESL1NCTMxxx91113126785

Page 25 - Order number Designation

Emotron AB 01-2550-01r3 Appendix 29Fig. 11 M10 example of auxiliary circuit when VDC is used.24VDC+0VDC-58762113119CTMxxxL3L2L1RESS1 S2L2L3L1 CNONCM10

Page 26

30 Appendix Emotron AB 01-2550-01r3

Page 28 - 11 Service

Emotron AB 01-2550-01r3 2009-09-15Emotron AB, Mörsaregatan 12, SE-250 24 Helsingborg, SwedenTel: +46 42 16 99 00, Fax: +46 42 16 99 49E-mail: info@emo

Page 29 - 12 Appendix

2 Emotron AB 01-2150-01r3

Page 30

Emotron AB 01-2550-01r3 Inside the box 31 Inside the boxPlease check the delivery. Despite the fact that all products from Emotron are carefully inspe

Page 31

4Safety Emotron AB 01-2550-01r32Safety• Read this manual thoroughly before installing and using the Emotron M10.• The Emotron M10 must be installed by

Page 32

Emotron AB 01-2550-01r3 Description 53 DescriptionThis instruction manual describes the installation and commissioning of the Emotron M10 shaft power

Page 33

6 Getting Started Emotron AB 01-2550-01r34 Getting Started4.1 Please take note of the safety section1. Pay special attention to the safety section in

Page 34 - Internet: www.emotron.com

Emotron AB 01-2550-01r3 Getting Started 712. Press and hold VAL for 3 seconds, at normal machine load. The Auto Set load level is automatically set an

Commentaires sur ces manuels